Air flow and complete combustion is ensured by air intakeson both sides. Overheat protection, automatic shutdown in case of overheat. It can be turned off briefly after 20 minutes of continuous use to avoid incomplete combustion due to low oxygen concentration.
Three controllers (gas, water and mode of operation) allow adjustment of gas volume, water volume and number of individual burners to improve combustion efficiency. Start with low water pressure.
The use of connecting rod control valve, even under low water pressure can be quickly started to meet the needs of water shortage areas and high-rise residential building users. Under high water pressure, the water flow can be slowed down steadily and the damage to internal parts can be reduced. When the water heater is unexpectedly turned off, the air source will be automatically cut off to ensure no gas leaks. The pipeline pressure can be released through the liquid pressure reducing valve to prevent false start.
After 20 minutes of continuous operation, the water heater will automatically shut down. It can be used normally after restarting.
When the heat exchanger temperature exceeds 80°C, the water heater automatically closes to prevent the equipment from overheating and the user from climbing. Built-inanti-freeze device can drain water from the water heater to prevent its internal components from freezing and damage at low temperatures. Applicable water pressure: 0.02-0.85Mpa. Inlet and outlet direction: Right in, left out. Item weight: about 4.5kg.
Detailed accessories are shown in the picture. Batteries are not included in the package. Before using the heater, please read the instructions carefully. Always retain the User's manual for future use. It is not only quality but also correct installation which will ensure that your heater works to. The heater must be in stalled and checked only by qualified and authorized technician. It is always advisable to install gas water heater outside the bathroom.In rare case, if it is to be installed inside the bathroom, ensure that there is sufficient Ventilation. The heater requires plentiful supply of fresh air for its efficient working. Inlets near the heater should never be obstructed or blocked. There should be at least one window or door which opens directly to the outside or out on to a. Air from outsides hall be able to enter the bathroom / location where the heater is installedthrough an inlet in a wall, door or window.
The section of the direct air inlet shall be at least 1.5sp. The burner viewing window should beat 1.4 to 1.5 metre height from the ground. There must be minimum distance of 1 feet between the top of the gas heater and ceiling of thewall for the easy removal offlue gases.